Emax(Max. capacity) | t | 0.5~25 | ||
Sensitivity | mV/V | 2.0±0.002 | ||
Accuracy class | C2 | C3 | ||
Maximum number of verification intervals | nmax | 2000 | 3000 | |
Minimum load cell verification interval | Vmin | Emax/2000 | Emax/3000 | |
Combined error | %F.S | ≤±0.020 | ≤±0.016 | |
Creep | %F.S/30min | ≤±0.020 | ≤±0.016 | |
Temperature effect on sensitivity | %F.S/10℃ | ≤±0.02 | ≤±0.017 | |
Temperature effect on zero | %F.S/10℃ | ≤±0.02 | ≤±0.017 | |
Zero balance | %F.S | ±1.0 | ||
Input resistance | Ω | 380±10Ω | ||
Output resistance | Ω | 350±3Ω | ||
Service temperature range | ℃ | -30...+70 | ||
Safe overload | %F.S | 120 | ||
Ultimate overload | %F.S | 200 | ||
Recommended excitation voltage | V | 5…15 | ||
Insulation resistance | MΩ/50V | >5000 | ||
Protection class | IP67;IP68 | |||
Load cell material | Alloy steel | |||
Cable length | m | 3(0.5~2t)/4(3t)/5(5t)/7(10t)/12(20t~25) | ||
Cable outer caliber | mm | Φ6 |