HY Explosion Proof Containerized Mobile Fuel Station Skid-mounted Container Fuel Petrol Diesel Filling Station
HY Explosion Proof Containerized Mobile Fuel Station Skid-mounted Filling Station for diesel, gasoline, etc.
1. The mobile fuel station is an explosion proof compact filling equipment for delivery /storage diesel, biodiesel, petrol, kerosene (diesel), etc.
2. It is made of filling machine, double layer tank, monitoring system and Oil and gas detection system, etc.
3. Widely used in logistics and freight transportation, bus passenger transportation, docks and yachts, industrial parks, fleets, new energy retail stations, coal mines, large construction sites, automobile driving schools, agricultural machinery cooperatives, concrete mixing stations and other fields.
Advantage:
1. The barrier and explosion-proof skid-mounted refueling device is composed of inner and outer double-layer tanks, with a firm structure and filled with anti-explosion materials. The oil tank is subjected to external forces such as fire, gunshot, and impact, and no explosion occurs. Secondly, when the container is ruptured and the oil spills and catches fire, repair welding with fire can also be carried out to ensure no leakage, deformation, and explosion. Among them, various emergency devices such as automatic fire extinguishers, emergency cut-off devices, low-temperature fuse devices, and emergency pressure relief devices can ensure the maximum safety in use under special circumstances.
2. The barrier and explosion-proof skid-mounted refueling device can store one or more oil products, and one or more refueling devices can be set to meet the oil needs of different customers. It can realize various functions such as oil storage, refueling, oil unloading, liquid level display, intelligent monitoring, and emergency shut-off.
3. Barrier explosion-proof skid-mounted refueling device, equipped with oil and gas recovery devices, and equipped with oil and gas detection systems in the control area and storage tank area, equipped with double-wall anti-leakage observation mirrors, which can monitor oil and gas in storage tanks and oil pipelines at any time Leakage, to avoid groundwater resources and air pollution caused by oil leakage.
4. Easy to operate, suitable for various oil-using environments. It can be equipped with an IC card back-end management system, which can deduct the amount in the card based on the amount of oil used.
Structure details
Double-layer tank
1. The equipment adopts double-layer tank design and uses the principle of double-layer tank body. It has excellent heat conduction and static electricity conduction function, which can effectively prevent the explosion accident of the oil storage tank under open flame, static electricity, impact and other events. The tank body is fire-resistant experiment. Continue to burn for 8 hours without deformation or cracking. And effectively avoid the leakage of internal liquid.
2. Adopting the splicing process and the double-layer brand strengthening process, the weld strength is higher than the butt weld strength of the 12mm thick steel plate
3. Q235B steel plate for use, the thickness of the tank wall is 6mm
Barrier explosion-proof material
The barrier explosion-proof material is filled in a container with a flammable and explosive medium at a fixed density, even if the air in the container is mixed with the corresponding flammable gas to reach the limit of explosion, it will encounter open flame, static electricity, violent impact, and gunshot. Explosion accidents will not occur in extreme situations such as, lightning strikes.
Monitoring system
1. The monitoring device is composed of a controller, a level gauge, a combustible gas sensor, an electrostatic grounding alarm device, and a strong current control part.
2. The controller is the core of the entire system, which receives the signal from the sensor and displays the current tank status information
3. The level gauge is responsible for measuring the level value in the tank, the combustible gas sensor measuring the concentration of combustible gas near the probe is transmitted to the controller in the form of 4-20mA, and the electrostatic grounding alarm is responsible for detecting the grounding state of the tanker in the unloading state .
4. The power control part is responsible for controlling external equipment such as fuel dispensers, oil unloading pumps, and lighting.
Explosion-proof refueling machine
1. Pass the national explosion-proof certification and measurement license certification.
2. Flow rate: gasoline 45 liters/minute, diesel 80 liters/minute,
3. Measuring accuracy: ±0.3%.
4. Equipped with emergency shut-off valve and pull-off valve to protect the fuel dispenser.
Suspended automatic fire extinguishing device
Ultra-fine dry powder fire extinguisher, filled with proper amount of driving gas-nitrogen, technical performance meets GA78-94 standard, temperature sensing glass nozzle at the nozzle of the device, starting temperature 68°c
Oil and gas detection system
The monitoring device collects and displays the combustible gas concentration values at three points in the oil tank in real time in the working state. When the combustible gas concentration exceeds the set upper limit, the controller sends out an audible and visual alarm signal to remind the operator to take measures to ensure the safety of the system