Enquiries
Message
Home > Products > Electrical Equipment & Supplies > Other Electrical Equipment
BF-2 automatic film width control air feeding control for film blowing machine blown film line
  • BF-2 automatic film width control air feeding control for film blowing machine blown film line
  • BF-2 automatic film width control air feeding control for film blowing machine blown film line
  • BF-2 automatic film width control air feeding control for film blowing machine blown film line
  • BF-2 automatic film width control air feeding control for film blowing machine blown film line
  • BF-2 automatic film width control air feeding control for film blowing machine blown film line

BF-2 automatic film width control air feeding control for film blowing machine blown film line

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Ruian City Hongchang Industry Control Equipment Co., Ltd.
Ruian City Hongchang Industry Control Equipment Co., Ltd.
China - Wenzhou
Manufacturing and trade
Trade Capacity
Export Percentage
50-70%
Nearest Port
Ningbo,Shanghai,Shenzhen
Accepted Delivery Terms
FOB,CFR,CIF,EXW,FAS,CIP,FCA,CPT,DEQ,DDP,DDU,Express,Delivery,DAF,DES
Employees
11-50 people
Accepted Payment Currency
USD,EUR,JPY,CAD,AUD,HKD,GBP,CNY,CNF
Average Lead Time
5 Day(s)
Certifications
CE
Product Specifications
Model Number
BF-2
Brand Name
HWGONGKONG
Product Description
Quick Details
Place of Origin:
Zhejiang, China
Brand Name:
HW
Model Number:
BF series
Supply Ability
Supply Ability:
50 Set/Sets per Week
BF Series Automatic Film Width Control System Air-feeding Type

Product Introduction

The BF series is the system to measure and control the lay-flat width on blown film production lines. This "air supplementary controller" uses a mechanical switch as the probe sensor to detect the size of the film, with a separate controller and solenoid valve.


Working Principle

The controller adopts imported integrated circuits, which can automatically control the width of the film during the production of the film blowing machine. When the film blown by the film blowing machine leaks from the system due to impurities and other reasons, resulting in the narrowing of the produced film, the sensor of the controller close to the film feeds back the signal to the host, and the host immediately controls to open the solenoid valve Inflate the membrane head and sound an alarm at the same time. When it is normal, turn off the solenoid valve and stop the alarm sound.

BF-2 automatic film width control air feeding control for film blowing machine blown film line from China supplier

BF-2 automatic film width control air feeding control for film blowing machine blown film line from China supplier

The proximity switch (to be chosen)

BF-2 automatic film width control air feeding control for film blowing machine blown film line from China supplier

BF-2 automatic film width control air feeding control for film blowing machine blown film line from China supplier


The package example

BF-2 automatic film width control air feeding control for film blowing machine blown film line from China supplier


Troubleshooting and Repair
1. When the film size is smaller than the set value, it is not inflated (the film size keeps getting smaller). Please check if the inflation indicator is on. If not, it means the sensitivity is too low or the sensor is broken.
If the light is on: please check if the throttle valve is closed, the gas source is not connected, and the solenoid valve coil is burned out.
2. The film size is larger than the set value and still inflated (the film size keeps getting bigger). Please check if the indicator light is off. If it is on: please place one or several films between the transmitter tube and the receiver tube in the sensor.
When the inflation indicator is off, it should not be inflated, but it will be inflated in the following situations: leakage in the solenoid valve, the normally open contact of the relay on the circuit board is always connected, etc., and the former is common.
3. There are three common cases of leakage in the solenoid valve: A. The air source is too dirty, and there is dirt on the valve core; B. The rubber seal in the valve core has cracks or deep depressions; C. If the air source pressure is too high, please note that the air pressure used by the controller must be less than 0.8 Mpa.


No desirable products?
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToKlara Zeng
Ruian City Hongchang Industry Control Equipment Co., Ltd.
Enquire
Supplier's popular products
Related Categories
Connectors&TerminalsElectronic&InstrumentEnclosuresFusesPowerAccessoriesPowerDistributionEquipmentProfessionalAudio,Video&Lighting
Popular Searches
tea bottling equipmentmodern dental lab equipmenttai chi equipmentholistic equipmentspeed skating equipmenthdpe electrical conduittyre service equipmentbin cleaning equipmentelectrical tajinegeotechnical equipmentused anesthesia equipment0 electrical wireschiller medical equipmentkernel medical equipmentelectrical turtlelowes electrical outletsreception equipmentecu laboratorial equipmentthermodynamics lab equipmentpaint testing equipmentice cream truck equipment0.3mm electrical wire0.3mm electrical wireink testing equipmentland leveling equipmentfan testing equipmentbeef jerky equipmentwater leak testing equipmentsteel plate handling equipmenttextile lab equipmentrubber vulcanizing equipmentround electrical ovencar electrical switchestj electrical socketmold lifting equipmentspark testing equipmentsolar lab equipmenthair salon electrical equipmentoven cleaning equipmentused rescue equipment